Relay Test Menu
This menu allows you to verify input closures and close the relays to verify connections. The
menu item is not listed and is activated by pressing [UP] and [DOWN] at the same time.
Closure Test
1. Press [ENTER] to enter the closure test
2. Press [UP] or [DOWN] to select the relay you want to test
Relay #1 selected, but not activated
3. Press [ENTER] to activate a relay – the box of the selected relay will darken
Relay #1 Activated
4. Press [ENTER] to clear the relay – the box of the selected relay will lighten
5. Press [BACK] to exit the closure test and return to the Settings submenu
When an input closure is closed, the appropriate box goes black and then clears after it is
released.
Input #1 closed, inputs #2 - #4 open
Resetting to Default Closures
When you are in the RELAY TEST menu, you can press [UP] and [DOWN] at the same time
to reset the closure map to its default setting.